New Product
Slim I/O Relay
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay
For the recent information on models that have been certified
for safety standards, refer to your OMRON website.
Refer to Safety Precautions on page 20.
Slim I/O Relay Types
G2RV-SR series mounted relay: electromagnetic relay ...... from page 2
G3RV-SR series mounted relay: solid state relay ................ from page 10
Common matter
Common Precautions
* According to OMRON actual measurement data from November 2015.
G3RV-SR
• Realized about 25% lower profile than conventional
products, contributing to further miniaturization of the
control panel.
• Push-In Plus technology are used to save wiring work in
comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with
traditional screw terminals.)
• No screw loosening means maintenance-free application,
realizing high reliability
• ‘Hand-free’ structure that holds an inserted flat-blade
screwdriver to achieve easier wiring work for stranded
wires.
• Screw terminal is also stocked to meet the screw type
needs.
• Mounted relay or solid-state relay has a plug-in terminal
that is difficult to bend at the time of exchange.
G2RV-SR
G2RV-SR/G3RV-SR
Common precautions ................................................................ from page 20
Common accessories (order separately)................................. from page 25
Common Accessories
1
Slim I/O Relay
G2RV-SR
G2RV-SR
Global standard size, low profile slim
I/O relay with width 6.2 mm
G3RV-SR
• Realized about 25% lower profile than conventional
products, contributing to further miniaturization of the
control panel.
• Realized opening and closing ability with one pole 6 A slim
shape.
• Micro load products for one pole 50 mA using Au-plated
contacts for small load switching also available.
• Since G2RV is a transparent case, confirming the state of
the contact with the naked eye is possible, and easy to
confirm abnormality on-site (installed location).
For the recent information on models that have been certified
• Screw terminal is also stocked to meet the screw type
for safety standards, refer to your OMRON website.
needs.
• Mounted relay uses plug-in terminals that are difficult to
bend when exchanging.
• G3RV-SR featuring a solid state relay similar in shape to G2RV-SR also available.
Refer to Safety Precautions on page 20.
Common Precautions
Features
Terminal x 5
• Push-in
• Screw
Release lever
Mechanical
indicator
• Operation
verification
which is linked
to the contact
Operation
display LED
(Socket section)
Push-In Plus technology
Protective cover
(Released state)
Protective cover
(Locked condition)
Latching lever
(Test switch)
Latching lever
(Test switch)
• Circuit check operation
Confirmation, reducing the inspection effort
PAT
Common Accessories
"Foreign matter intrusion prevention structure"
"Malfunction prevention stopper"
Transparent case
Relay contact
Easy confirmation
of the situation
Release lever
Relay easily
fixed/removed
90 mm
80 mm
2
With latching lever
(Test switch)
Standard model/Micro load
Plug-in terminal
Peace of mind as the
terminal does not bend
when replacing
Short bar insertion holes
Release hole
Terminal (insertion) hole
G2RV-SR
Model Number Structure
Model Number Legend
(1)
(2)
(3) (4)
(5)
(6)
(1) Basic model name
G2RV: Slim I/O Relay
(2) Sub type
SR: Slim relay + integrated low profile socket
(3) Terminal (wire connection)
50: Push-In Plus Terminal
70: Screw terminal
(5) Contact structure
Blank: Standard
AP: Microloads
(4) Latching lever (test switch)
0: Without latching lever
1: With latching lever
(6) Rated input voltage
12, 24 VDC
24, 48 VAC/VC
100, 110, 200, 230 VAC
G2RV-SR
G2RV-SR @@ @ - @ @
Ordering Information
Terminal
(Wire connection)
Latching lever
(Test switch)
Classification
Rated input voltage (V)
G2RV-SR500 DC24
24
G2RV-SR500 AC/DC24
48
G2RV-SR500 AC/DC48
100
G2RV-SR500 AC100
110
G2RV-SR500 AC110
200
G2RV-SR500 AC200
230
G2RV-SR500 AC230
DC
24
G2RV-SR501 DC24
AC/DC
24
G2RV-SR501 AC/DC24
12
G2RV-SR500-AP DC12
24
G2RV-SR500-AP DC24
24
G2RV-SR500-AP AC/DC24
AC/DC
No
Standard
AC
Yes
DC
AC/DC
Microloads
G2RV-SR500-AP AC/DC48
100
G2RV-SR500-AP AC100
110
G2RV-SR500-AP AC110
200
G2RV-SR500-AP AC200
230
G2RV-SR500-AP AC230
12
G2RV-SR700 DC12
24
G2RV-SR700 DC24
24
G2RV-SR700 AC/DC24
48
G2RV-SR700 AC/DC48
100
G2RV-SR700 AC100
110
G2RV-SR700 AC110
200
G2RV-SR700 AC200
230
G2RV-SR700 AC230
DC
24
G2RV-SR701 DC24
AC/DC
24
G2RV-SR701 AC/DC24
12
G2RV-SR700-AP DC12
24
G2RV-SR700-AP DC24
24
G2RV-SR700-AP AC/DC24
No
AC
DC
AC/DC
No
Standard
AC
Yes
Screw terminal
DC
AC/DC
Microloads
No
AC
Note: Sockets are not sold individually.
48
G2RV-SR700-AP AC/DC48
100
G2RV-SR700-AP AC100
110
G2RV-SR700-AP AC110
200
G2RV-SR700-AP AC200
230
G2RV-SR700-AP AC230
Common Accessories
48
Common Precautions
G2RV-SR500 DC12
24
G3RV-SR
12
DC
Push-In Plus
Terminal
Model
3
G2RV-SR
Relay for Maintenance
G2RV-SR
Model Number Legend
G2RV-1 - S @ - @ - G @
(1) (2) (3)
(4)
(5)
(1) No. of poles
1: 1 pole
G2RV-1-SI-G
G2RV-1-S(-AP)-G
(6)
(4) Contact material
Blank: Ag alloy
AP: Ag alloy + Au plating
(2) Terminal
S: plug-in
(3) Latching lever (Test switch)
Blank: Without latching lever
I: With latching lever
(5) Types of relay for exchange
G: G2RV-SR series equipped
Relay
(6) Rated coil voltage
Number: 11, 21, 48 VDC
List of Models
G3RV-SR
Type
Latching
Lever
(Test switch)
No
Rated coil
voltage (V)
Model
11
G2RV-1-S-G DC11
21
G2RV-1-S-G DC21
G2RV-SR700/500 DC12V
G2RV-SR700/500 DC24V
G2RV-SR700/500 AC/DC24V
G2RV-SR700/500 AC/DC48V
DC
Standard
Applicable model
G2RV-SR700/500 AC100V
48
G2RV-1-S-G DC48
G2RV-SR700/500 AC110V
G2RV-SR700/500 AC200V
G2RV-SR700/500 AC230V
Common Precautions
Yes
Microload No
DC
21
G2RV-1-SI-G DC21
11
G2RV-1-S-AP-G DC11
21
G2RV-1-S-AP-G DC21
G2RV-SR701/501 AC/DC24V
G2RV-SR700/500-AP DC12V
G2RV-SR700/500-AP DC24V
G2RV-SR700/500-AP AC/DC24V
G2RV-SR700/500-AP AC/DC48V
DC
G2RV-SR700/500-AP AC100V
48
G2RV-1-S-AP-G DC48
G2RV-SR700/500-AP AC110V
G2RV-SR700/500-AP AC200V
G2RV-SR700/500-AP AC230V
Note: Voltage is reduced within the socket for the slim I/O relay, so the rated input voltage and rated coil voltage of replacement relays are different.
Accessories (order separately)
Refer to page 25 for G2RV-SR/G3RV-SR Common Accessories.
Common Accessories
4
G2RV-SR701/501 DC24V
G2RV-SR
Specifications
Ratings
Must operate
voltage
Rated current
Rated input
voltage
AC
50 Hz
DC
60 Hz
Must release
voltage
Percentage of the rated voltage
Power consumption
Maximum
allowable voltage
AC (VA)
Percentage of the
rated voltage
DC (mW)
12 VDC
–
–
27.9 mA
–
Approx. 300 mW
24 VDC
–
–
13.5 mA
–
Approx. 300 mW
24 VAC/VDC
12.5 mA 12.6 mA
12.6 mA
Approx. 0.5 VA Approx. 300 mW
48 VAC/VDC
5.9 mA
6.1 mA
5.2 mA
100 VAC
5.9 mA
6.0 mA
–
110 VAC
5.9 mA
5.9 mA
–
Approx. 0.8 VA –
200 VAC
6.6 mA
7.6 mA
–
Approx. 1.7 VA –
230 VAC
7.3 mA
8.4 mA
–
Approx. 1.7 VA –
80% max.*
Approx. 0.4 VA Approx. 250 mW
10% min.
Approx. 0.8 VA –
110%
Contact ratings
Standard (G2RV-SR700, 500, 701, 501)
For microloads (G2RV-SR700-AP, 500-AP) *2
SPDT
Load
Resistive load
(cosφ=1)
Inductive load
(cosφ=0.4, L/R=7ms)
Resistive load
(cosφ=1)
Rated load
6 A at 250 VAC
6 A at 30 VDC
2.5 A at 250 VAC
2 A at 30 VDC
50 mA at 30 VAC
50 mA at 36 VDC
Rated carry current
6A
50 mA
Maximum switching voltage
440 VAC, 125 VDC
30 VAC, 36 VDC
Maximum switching current
6A
Maximum switching power
1,500 VA
180 W
Failure rate P value
(reference value) *1
10 mA at 5 VDC
50 mA
500 VA
60 W
–
1 mA at 100 mVDC
*1. P level: λ60=0.1×10 /times
This value is the value in switching frequency 120 operations/min.
*2. If the Au plating layer is destroyed, the number will be the same as the standard type.
-6
Characteristics
Item
Standard (G2RV-SR700, 500, 701, 501)
For microloads (G2RV-SR700-AP, 500-AP)
100 m Ω max.
Operate (Set) time *
20 ms max.
Release time *
AC, AC/DC: 40 ms max.
DC: 20 ms max.
Maximum operating frequency
Mechanical: 18,000 operations/h
Electrical: 1,800 operations/h (rated load)
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
Between coil and contacts: 4,000VAC 50/60 Hz 1 min
Contact between the same polarity: 1,000 VAC 50/60 Hz 1 min
Vibration resistance
Destruction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Malfunction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Shock resistance
Destruction: 1,000 m/s2
Malfunction: Energized 200m/s2, Non-energized 100m/s2
Endurance *
Mechanical
5,000,000 operations min.
Electrical
NO contact: 70,000 operations min.
NC contact: 50,000 operations min.
5,000,000 operations min.
Ambient operating temperature
Operating: –40 to +55°C (with no icing or condensation)
Ambient operating humidity
Operating: 5 to 85% RH
Weight
Approx. 30 g
Contact material
Ag alloy
Common Accessories
Contact resistance *
Common Precautions
Contact configuration
G3RV-SR
Note: The operating characteristics are measured at ambient temperature of 23°C.
* Operating voltage will be, for mounting in the upside down direction, 85% max.
(Upside down: Direction in which the mechanical indicator faces down)
Item
G2RV-SR
Coil ratings
Ag alloy + Au plating
Note: Above values are initial values.
* Value is at ambient temperature of 23°C.
5
G2RV-SR
Approved standards
G2RV-SR
UL508 (file No.E41643)
Model
Contact form
G2RV-SR series
Operation coil ratings
12 to 48 VDC
24 to 230 VAC
SPDT
Contact ratings
Operations
6 A at 250 VAC (Resistive load)
6 A at 30 VDC (Resistive load)
2 A at 400 VAC (Resistive load)*
* If the load voltage exceeds 250 VAC, please attach with a spacing
of 12 mm min., or use a separate plate (XW5Z-EP12).
6,000
12 mm 12 mm 12 mm
TÜV (EN 61810-1)
\
Model
Contact form
SPDT
Operations
50,000
50,000
6,000
12 mm 12 mm 12 mm
Model
Contact form
Operation coil ratings
Contact ratings
6 A at 250 VAC (Resistive load)
G2RV-SR500
G2RV-SR700
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
SPDT
2.5 A at 250 VAC (PF0.4)
6 A at 30 VAC (Ress)
2 A at 30 VDC (L/R=7ms)
6 A at 250 VAC (Resistive load)
G2RV-SR501
G2RV-SR701
SPDT
12, 24 VDC
24 VAC/VDC
SPDT
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
2.5 A at 250 VAC (PF0.4)
6 A at 30 VAC (Ress)
2 A at 30 VDC (L/R=7ms)
G2RV-SR500-AP
G2RV-SR700-AP
0.05 A at 30 VAC (Resistive load)
0.05 A at 36 VDC (Resistive load)
Common Accessories
Engineering Data
Endurance curve (N.O. side)
Switching capacity of DC resistive load
1000
30 VDC resistive load
250 VAC resistive load
DC breaking current (A)
Common Precautions
Lloyd's (File No.07/10020)
10.0
1.0
100
30 VDC
inductive load
250 VAC inductive load
10
0
0.1
2
4
6
Opening and closing current (A)
6
Contact ratings
6 A at 250 VAC (Resistive load)
6 A at 30 VDC (Resistive load)
2 A at 400 VAC (Resistive load)*
* If the load voltage exceeds 250 VAC, please attach with a spacing
of 12 mm min., or use a separate plate (XW5Z-EP12).
Number of operations (x 103 operations)
G3RV-SR
G2RV-SR series
Operation coil ratings
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
20
60
100
140
180
220
DC switching voltage (V)
G2RV-SR
Dimensions
(unit: mm)
Slim I/O Relay + socket
Push-In Plus Terminal Block
Terminal Arrangement/Internal Connection Diagram
(TOP VIEW)
12 VDC
(+) Input circuit
A1
G2RV-SR
Models without latching lever (without test switch)
G2RV-SR500
78 max.
G2RV-SR500-AP
A2
G2RV
3.4
(–)
74.5
74.1
Other voltage
35.25
18.78
(5.05)
Input circuit
A1
G2RV
12
A2
14
11
78.77
G3RV-SR
90 max.
35.3
24 VDC
(+) Input circuit
12
A1
14
A2
G2RV
11
(–)
: Diode bridge
(5.05)
: Light emitting diode
18.78
6.2 max.
35.25
51.72
59.71
12
14
11
Models with latching lever (with test switch)
G2RV-SR501
Terminal Arrangement/Internal Connection Diagram
(TOP VIEW)
12 VDC
81 max.
(+)
Input circuit
A1
A2
G2RV
3.4
(5.05)
(–)
77.5
74.1
Other voltage
35.25
18.78
Input circuit
A1
G2RV
12
A2
11
78.77
24 VDC
90 max.
(+)
A1
A2
G2RV
(–)
Input circuit
12
14
11
: Diode bridge
(5.05)
: Light emitting diode
18.78
6.2 max.
35.25
51.72
59.71
12
Common Accessories
14
35.3
Common Precautions
Note: For recommended ferrules, crimp tools, and types and gauges of wires,
refer to 3. Recommended Ferrules and Crimp Tools on page 23.
14
Note: For recommended ferrules, crimp tools, and types and gauges of wires,
refer to 3. Recommended Ferrules and Crimp Tools on page 23.
11
7
G2RV-SR
Screw terminal
G2RV-SR
Models without latching lever (without test switch)
G2RV-SR700
G2RV-SR700-AP
Terminal Arrangement/Internal Connection Diagram
(TOP VIEW)
12 VDC
(+)
78 max.
G2RV
3.4
Input circuit
A1
74.5
A2
(–)
Other voltage
74.1
35.18
Input circuit
18.71
(5.05)
A1
G2RV
12
A2
14
11
78.77
35.3
90 max.
G3RV-SR
24 VDC
(+)
Input circuit
12
A1
14
A2
G2RV
11
(–)
: Diode bridge
(5.05)
18.71
: Light emitting diode
35.18
6.2 max.
51.65
56.2
12
14
Common Precautions
Note: For recommended ferrules, crimp tools, and types and gauges of wires,
refer to 3. Recommended Ferrules and Crimp Tools on page 23.
11
Models with latching lever (with test switch)
G2RV-SR701
Terminal Arrangement/Internal Connection Diagram
(TOP VIEW)
12 VDC
(+)
81 max.
Input circuit
A1
G2RV
3.4
A2
(–)
77.5
Other voltage
74.1
35.18
(5.05)
Input circuit
18.71
A1
G2RV
12
A2
14
Common Accessories
11
78.77
35.3
(+)
A1
A2
G2RV
(–)
Input circuit
12
14
11
: Diode bridge
(5.05)
18.71
: Light emitting diode
35.18
6.2 max.
51.65
56.2
12
14
Note: For recommended ferrules, crimp tools, and types and gauges of wires,
refer to 3. Recommended Ferrules and Crimp Tools on page 23.
8
24 VDC
90 max.
11
G2RV-SR
Relay for maintenance
5.2 max.
G2RV-SR
Models without latching lever
G2RV-1-S-G
G2RV-1-S-AP-G
30.5 max.
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
33 max.
16.2
0.5
14 11 12
A1 A2
G3RV-SR
1.8
(Input circuit)
2.4
3.5
5.04
5.04
22
3
Models with latching lever (test switch)
G2RV-1-SI-G
30.5 max.
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
(Input circuit)
36 max.
14 11 12
16.2
1.8
A1 A2
Common Precautions
5.2 max.
0.5
2.4
5.04
5.04
22
3
Common Accessories
3.5
9
Slim I/O Solid State Relay
G2RV-SR
G3RV-SR
Global standard size, low profile type
slim I/O solid state relay with width
6.2 mm.
G3RV-SR
• Realized about 25% lower profile than conventional products,
contributing to further miniaturization of the control panel.
• Optimal slim, high frequency, high-speed opening and closing
SSR (solid state relay).
• Realized a slim shape with a switching capacity up to
3 A (DC), and 2 A (AC).
• Because MOSFET is used for the outlet element for the DC
load, opening and closing load of 100 μA to 3 A is possible.
• Check operating status at a glance at the operating display
LED.
For the recent information on models that have been certified
• Mounted I/O SSR (solid-state relay) uses plug-in terminals that
for safety standards, refer to your OMRON website.
are difficult to bend when exchanging.
• G2RV-SR featuring a general-purpose relay similar in shape to G3RV-SR also available.
Refer to Safety Precautions on page 20.
Common Precautions
Features
Common Accessories
10
Push-In Plus technology
Terminal x 5
• Push-in
• Screw
Short bar insertion holes
Release lever
Operation display LED
(Socket section)
Release hole
Operation
display LED
(SSR section)
Terminal (insertion) hole
Release lever
Relay easily
fixed/removed
90 mm
80 mm
Plug-in terminal
Peace of mind as the terminal
does not bend when replacing
G3RV-SR
Model Number Structure
Model Number Legend
(1)
(2)
(3)
(4)
(5)
(1) Basic model name
G3RV: Slim I/O Solid State Relay
(2) Sub type
SR: Slim solid relay + integrated low profile socket
(3) Terminal (wire connection)
500: Push-In Plus Terminal
700: Screw terminal
(4) Output voltage specification
A : AC output (triac) zero cross function available
AL : AC output (triac) zero cross function not available
D : DC output (MOS FET)
G2RV-SR
G3RV-SR @ @ @ - @ @
(5) Rated voltage input
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
G3RV-SR
Common Precautions
Common Accessories
11
G3RV-SR
Ordering Information
Terminal
(wire connection)
Applicable
output load
Zero cross
function
Rated input voltage
(V)
G2RV-SR
DC
AC/DC
DC load
—
AC
DC
AC/DC
Push-In Plus Terminal
Yes
G3RV-SR
AC
AC load
DC
AC/DC
No
AC
Common Precautions
DC
AC/DC
DC load
—
AC
DC
AC/DC
Screw terminal
Yes
Common Accessories
AC
AC load
DC
AC/DC
No
AC
Note: Sockets are not sold individually.
12
Model
12
G3RV-SR500-D DC12
24
G3RV-SR500-D DC24
24
G3RV-SR500-D AC/DC24
48
G3RV-SR500-D AC/DC48
100
G3RV-SR500-D AC100
110
G3RV-SR500-D AC110
200
G3RV-SR500-D AC200
230
G3RV-SR500-D AC230
12
G3RV-SR500-A DC12
24
G3RV-SR500-A DC24
24
G3RV-SR500-A AC/DC24
48
G3RV-SR500-A AC/DC48
100
G3RV-SR500-A AC100
110
G3RV-SR500-A AC110
200
G3RV-SR500-A AC200
230
G3RV-SR500-A AC230
12
G3RV-SR500-AL DC12
24
G3RV-SR500-AL DC24
24
G3RV-SR500-AL AC/DC24
48
G3RV-SR500-AL AC/DC48
100
G3RV-SR500-AL AC100
110
G3RV-SR500-AL AC110
200
G3RV-SR500-AL AC200
230
G3RV-SR500-AL AC230
12
G3RV-SR700-D DC12
24
G3RV-SR700-D DC24
24
G3RV-SR700-D AC/DC24
48
G3RV-SR700-D AC/DC48
100
G3RV-SR700-D AC100
110
G3RV-SR700-D AC110
200
G3RV-SR700-D AC200
230
G3RV-SR700-D AC230
12
G3RV-SR700-A DC12
24
G3RV-SR700-A DC24
24
G3RV-SR700-A AC/DC24
48
G3RV-SR700-A AC/DC48
100
G3RV-SR700-A AC100
110
G3RV-SR700-A AC110
200
G3RV-SR700-A AC200
230
G3RV-SR700-A AC230
12
G3RV-SR700-AL DC12
24
G3RV-SR700-AL DC24
24
G3RV-SR700-AL AC/DC24
48
G3RV-SR700-AL AC/DC48
100
G3RV-SR700-AL AC100
110
G3RV-SR700-AL AC110
200
G3RV-SR700-AL AC200
230
G3RV-SR700-AL AC230
G3RV-SR
Solid state relay for maintenance
G2RV-SR
Model Number Legend
G3RV-@ @ S @ @
(1) (2) (3) (4)
(1) Output voltage
specification
D: DC output
2: AC output
(5)
(3) Terminal
S: Plug-in type
(4) Zero cross functions
Blank: Zero cross function available
L: Zero cross function not available
(2) Rated current
02: AC output 2 A
03: DC output 3 A
(5) Rated input voltage
Number: 12, 24, 48 VDC
List of Models
Rated
output
Load *
Rated input
voltage
(socket)
12 VDC
24 VDC
24 VAC/VDC
Model
G3RV-202S DC12
G3RV-202S DC24
48 VAC/VDC
Yes
Phototriac
AC
Yes
(green)
G3RV-SR700/500-A AC200V
G3RV-SR700/500-A AC230V
G3RV-202SL DC12
G3RV-202SL DC24
48 VAC/VDC
No
24 VAC/VDC
Photovoltage
coupler
DC
–
3A
(at 5 to
24 VDC)
G3RV-SR700/500-AL AC230V
G3RV-D03SL DC12
G3RV-D03SL DC24
48 VAC/VDC
G3RV-SR700/500-D DC12V
G3RV-SR700/500-D DC24V
G3RV-SR700/500-D AC/DC24V
G3RV-SR700/500-D AC/DC48V
100 VAC
110 VAC
G3RV-SR700/500-AL AC110V
G3RV-SR700/500-AL AC200V
230 VAC
24 VDC
G3RV-SR700/500-AL DC24V
G3RV-SR700/500-AL AC/DC24V
G3RV-SR700/500-AL AC100V
G3RV-202SL DC48
200 VAC
12 VDC
G3RV-SR700/500-AL DC12V
G3RV-SR700/500-AL AC/DC48V
100 VAC
110 VAC
G3RV-SR700/500-A AC110V
G3RV-SR700/500-D AC100V
G3RV-D03SL DC48
G3RV-SR700/500-D AC110V
G3RV-SR700/500-D AC200V
230 VAC
G3RV-SR700/500-D AC230V
* Different depending on the ambient temperature.
For more details, refer to Load current vs. ambient rated temperature on page 16.
Refer to page 25 for G2RV-SR/G3RV-SR Common Accessories.
Common Accessories
200 VAC
Accessories (order separately)
Common Precautions
24 VAC/VDC
G3RV-SR700/500-A DC24V
G3RV-SR700/500-A AC/DC24V
G3RV-SR700/500-A AC100V
G3RV-202S DC48
200 VAC
2A
(at 100 to 230 VAC
240
12 VDC
VAC)
24 VDC
G3RV-SR700/500-A DC12V
G3RV-SR700/500-A AC/DC48V
100 VAC
110 VAC
Applicable model
G3RV-SR
Insulation Operation Output Zero cross
method Display (SSR) Function
13
G3RV-SR
Specifications
Rating (ambient temperature 25°C)
G2RV-SR
Input
G3RV-SR700/500-A series
Rated current
Rated input
voltage
AC
50 Hz
DC
60 Hz
Must operate
voltage
12 VDC
–
–
15.0 mA
10.8 V max.
24 VDC
–
–
12.0 mA
21.6 V max.
24 VAC/VDC
11.3 mA
11.4 mA
11.0 mA
21.6 V max.
48 VAC/VDC
6.8 mA
6.9 mA
6.0 mA
43.2 V max.
100 VAC
6.2 mA
6.2 mA
–
90 V max.
110 VAC
6.2 mA
6.2 mA
–
99 V max.
200 VAC
6.7 mA
7.9 mA
–
180 V max.
230 VAC
7.5 mA
8.8 mA
–
207 V max.
Must release
voltage
1 V min.
Input voltage
Percentage of the
rated voltage
±10%
G3RV-SR
G3RV-SR700/500-AL series
Rated current
Rated input
voltage
12 VDC
AC
50 Hz
–
DC
60 Hz
–
Must operate
voltage
15.0 mA
10.8 V max.
24 VDC
–
–
12.0 mA
21.6 V max.
24 VAC/VDC
11.4 mA
11.5 mA
11.0 mA
21.6 V max.
Common Precautions
48 VAC/VDC
7.7 mA
7.7 mA
6.9 mA
43.2 V max.
100 VAC
7.3 mA
7.3 mA
–
90 V max.
110 VAC
7.3 mA
7.3 mA
–
99 V max.
200 VAC
7.0 mA
8.1 mA
–
180 V max.
230 VAC
7.7 mA
8.9 mA
–
207 V max.
Must release
voltage
1 V min.
Input voltage
Percentage of the
rated voltage
±10%
G3RV-SR700/500-D series
Rated current
Rated input
voltage
AC
50 Hz
DC
60 Hz
Must operate
voltage
Common Accessories
12 VDC
–
–
8.0 mA
10.8 V max.
24 VDC
–
–
4.6 mA
21.6 V max.
24 VAC/VDC
5.0 mA
5.1 mA
4.3 mA
21.6 V max.
48 VAC/VDC
6.8 mA
6.9 mA
6.0 mA
43.2 V max.
100 VAC
6.2 mA
6.2 mA
–
90 V max.
110 VAC
6.2 mA
6.2 mA
–
99 V max.
200 VAC
6.7 mA
7.9 mA
–
180 V max.
230 VAC
7.5 mA
8.8 mA
–
207 V max.
Must release
voltage
1 V min.
Input voltage
Percentage of the
rated voltage
±10%
Output
14
Item
G3RV-SR700/500-A(L)
G3RV-SR700/500-D
Rated load voltage
100 to 240 VAC (50/60 Hz)
5 to 24 VDC
Load voltage range
75 to 264 VAC (50/60 Hz)
3 to 26.4 VDC
Load current
0.1 to 2 A (Ambient temperature=25°C) 100 μA to 3 A (Ambient temperature=25°C)
Inrush current resistance
30 A (60 Hz, 1 cycle)
30 A (60 Hz, 1 cycle)
Permissible l2t; Joule integral value
(reference value)
15A2s
9 A2 s
Applied load capacity
400 W
(Output voltage: 200 VAC)
72 W
(Output voltage: 24 VDC)
G3RV-SR
Characteristics
G3RV-SR700/500-A
G3RV-SR700/500-AL
G3RV-SR700/500-D
Operate time
1/2 cycle of load power supply
+1 ms max.
3 ms max.
6 ms max.
Release time
60 ms max.
60 ms max.
60 ms max.
Output ON voltage drop
1.6 V (RMS) max.
Output ON resistance
–
0.3 Ω max. (at 24 VDC)
–
5 mA max. (at 200 VAC, 50/60 Hz)
10 µA max. (at 24 VDC)
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
Between input and output 2,500 VAC 50/60 Hz 1 min
Vibration resistance
Malfunction: 10 to 55 to 10 Hz double amplitude 0.70 mm
Shock resistance
300m/s2
Ambient operating temperature
Storage: –30 to +100°C (with no icing or no condensation)
Operating: –30 to +55°C (with no icing or no condensation)
Ambient operating humidity
45 to 85% RH
Weight
Approx. 38 g
Pollution degree
2
The degree of protection by
IEC60529
IP20
Rated impulse dielectric
strength
4.0 kV/III
Load category
LC-A
Overload current profile
1.5Ie 1.1Ue
5s ON, 10s OFF, 10 cycles
Rated insulation voltage
240 V
G3RV-SR
Leaked current
DC-12
UL 508 (file No.E64562)
Input ratings
Contact ratings
G3RV-SR700/500-D series
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
24 VDC 3 A (resistive load) at 25°C
G3RV-SR700/500-A(L) series
12, 24 VDC
24, 48 VAC/DC
100, 110, 200, 230 VAC
240 VAC 2 A (resistive load) at 25°C
TÜV(EN 62314)
Model
Input ratings
Contact ratings
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
24 VDC 3 A (resistive load)
G3RV-SR700/500-A(L) series
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
240 VAC 2 A (resistive load)
Common Accessories
G3RV-SR700/500-D series
Common Precautions
Approved standards
Model
G2RV-SR
Item
15
G3RV-SR
Engineering Data
Load current vs. ambient rated temperature
Product mounting spacing 10 mm (Separate Mounting)
Close mounting (up to 5 units *)
5
Load current (A)
Load current (A)
G2RV-SR
G3RV-SR700/500-A(L) series
4
5
4
3
3
2
2
1
1
0
−30 −20
0
20 25
40
55 60
80
0.2
0
−30 −20
100
0
20 25
Ambient temperature (°C)
40
55 60
80
100
Ambient temperature (°C)
Close mounting (up to 5 units *)
Load current (A)
Load current (A)
Product mounting spacing 10 mm (Separate Mounting)
5
4
5
4
3
3
2
2
1
0.5
0
−30 −20
0
20 25
40
55 60
80
0
−30 −20
100
0
20 25
Ambient temperature (°C)
40
55 60
80
100
Ambient temperature (°C)
* When five or more are installed, install with 10 mm space between
each.
For details, please refer to Mounting on page 23.
Inrush Current Resistance: Non-repetitive
Keep the inrush current to below the inrush current resistance value (i.e., below the broken line) if it occurs repetitively.
Common Accessories
16
G3RV-SR700/500-A(L) series
G3RV-SR700/500-D series
40
Inrush current (A.Peak)
Common Precautions
1
Inrush current (A.Peak)
G3RV-SR
G3RV-SR700/500-D series
35
30
25
40
35
30
25
20
20
15
15
10
10
5
5
0
10
30 50
100
300 500 1,000
3,000 5,000
Energized time (ms)
0
10
30 50
100
300 500 1,000
3,000 5,000
Energized time (ms)
G3RV-SR
Dimensions
(unit: mm)
Solid state relay + socket
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
12 VDC
G2RV-SR
Push-In Plus Terminal Block
G3RV-SR500
(+) Input circuit
78 max.
A1
G3RV
A2
A2–
3.4
(5.05)
(–)
INPUT
74.5
74.1
A1+
13 (+)
35.25
18.78
OUTPUT
14 (–)
12
14
13
78.77
24 VDC
90 max.
35.3
(+)
Input circuit
G3RV-SR
The information in
parentheses in for
a DC output.
A1
G3RV
A2
(–)
A2–
INPUT
(5.05)
A1+
18.78
6.2 max.
35.25
OUTPUT
14 (–)
59.71
The information in
parentheses in for
a DC output.
12
14
13
Other voltage
Input circuit
A1
G3RV
A2
A2–
Common Precautions
51.72
13 (+)
INPUT
A1+
13 (+)
14 (–)
The information in
parentheses in for
a DC output.
12
14
13
Note: For recommended ferrules, crimp tools, and types and gauges of wires,
refer to 3. Recommended Ferrules and Crimp Tools on page 23.
: Diode bridge
: Light emitting diode
Common Accessories
OUTPUT
17
G3RV-SR
Screw terminal
G3RV-SR700
G2RV-SR
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
12 VDC
78 max.
(+)
Input circuit
A1
3.4
74.5
G3RV
74.1
35.18
(5.05)
A2
A2–
18.71
(–)
INPUT
A1+
13 (+)
OUTPUT
14 (–)
G3RV-SR
78.77
35.3
90 max.
The information in
parentheses in for
a DC output.
12
14
13
24 VDC
(+)
Input circuit
A1
(5.05)
18.71
G3RV
35.18
A2
6.2 max.
(–)
51.65
56.2
A2–
INPUT
A1+
13 (+)
Common Precautions
OUTPUT
14 (–)
The information in
parentheses in for
a DC output.
12
14
13
Other voltage
Input circuit
A1
G3RV
A2
A2–
INPUT
A1+
13 (+)
Common Accessories
18
OUTPUT
14 (–)
The information in
parentheses in for
a DC output.
12
14
13
Note: For recommended ferrules, crimp tools, and types and gauges of wires,
refer to 3. Recommended Ferrules and Crimp Tools on page 23.
: Diode bridge
: Light emitting diode
G3RV-SR
Solid state relay for maintenance
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
G3RV-D03SL (input circuit)
Input
30.5 max.
Load
G2RV-SR
G3RV-D03SL
G3RV-202S(L)
33 max.
15.8
14
1.8
3.5
13
A1 A2
G3RV-202S(L) (input circuit)
2.4
22
5.04
3
Input
5.2 max.
Load
13
A1 A2
G3RV-SR
14
Common Precautions
Common Accessories
19
G2RV-SR/G3RV-SR
Safety Precautions
Be sure to read the Safety Precautions for All Relays in the website at the following URL:
http://www.ia.omron.com/.
G2RV-SR
Format of Warning Indications
WARNING
Indicates a potentially hazardous situation
which, if not avoided, will result in minor or
moderate injury, or may result in serious
injury or death. Additionally, there may be
significant property damage.
CAUTION
Indicates a potentially hazardous situation
which, if not avoided, may result in minor or
moderate injury or in property damage.
Precautions
for Safe Use
Indicates supplementary comments on
what to do or avoid doing, to use the
product safety.
Precautions
for Correct
Use
Includes operating precautions to ensure
that the product will operate properly and
that performance and functions will not be
adversely affected.
G3RV-SR
Meaning of Graphic Symbols for Ensuring Product Safety
Indicates the possibility of electric shock under
specific conditions.
Used for general CAUTION, WARNING, or
DANGER precautions for which there is no
specified symbol. (This symbol is also used as
the alerting symbol, but shall not be used in this
meaning on the product.)
Indicates the possibility of explosion or rupture
under specific conditions.
Common Precautions
Common Accessories
20
Indicates the possibility of injuries by high
temperature under specific conditions.
WARNING
Ensure that the socket is not charged during wiring and
maintenance. Not doing so may result in electric shock.
Do not touch the terminal section of the G2RV-SR or the
surrounding area while the power is being supplied.
Doing so may result in electric shock.
CAUTION
Minor electrical shock may occasionally occur.
Do not touch the G3RV terminal section (i.e., current
carrying parts) while the power is being supplied.
The G3RV may rupture if short-circuit current flows.
As protection against accidents due to short-circuiting,
be sure to install protective devices, such as fuses and
no-fuse breakers, on the power supply side.
Minor electrical shock may occasionally occur.
Do not touch the main circuit terminals on the G3RV
immediately after the power supply has been turned
OFF.
Shock may result due to the electrical charge stored
in the built-in snubber circuit.
Note: G3RV-202S(L), G3RV-SR500/700-A(L) series
models only
Minor burns may occasionally occur.
Do not touch the G3RV or the heat sink while the
power is being supplied or immediately after the
power supply has been turned OFF.
The G3RV becomes extremely hot.
Provide a space of at least 3 mm between the G2RVSR and ground. Not doing so may result in a ground
fault.
G2RV-SR/G3RV-SR
Precautions for Safe Use
G2RV-SR
Transport
• Do not use the product if it has been dropped on the ground.
Dropping the product may adversely affect performance.
• Do not drop the product or subject it to abnormal vibration or shock
during transportation or mounting. Doing so may result in
deterioration of performance, malfunction, or failure.
• Do not transport the product without it being packaged. Doing so
may result in damage, malfunction, or failure.
• Do not transport the G3RV under the following conditions. Doing
so may result in damage, malfunction, or deterioration of
performance characteristics.
• High temperature, high humidity conditions
• Conditions such as temperature change that causes rapid
condensation
• Condition where it is not packaged
• Do not use or store the product in the following locations. Doing so
may result in damage, malfunction, or deterioration of performance
characteristics.
• Do not store in locations subject to ambient storage
temperatures outside the range –40 to 70°C (for G2RV) and
outside the range –30 to 100°C (for G3RV).
• Locations subject to relative humidity outside the range 5% to
85% (for G2RV) and outside the range 45% to 85% (for G3RV).
• Locations subject to high temperature or high humidity.
• Conditions such as temperature change that causes rapid
• Locations where corrosive gases or flammable gases are present
• Location where rainwater or water droplets gets splashed
• Location with splashes of water, oil, and chemicals, etc.
• Locations with much dust, salt, and iron powder
• Location with blockers
• Where static electricity or noise occurs
in damage, malfunction, or failure.
• Please use the power of the rated frequency. It may cause
malfunction, failure, or risk of burnout.
• Install G3RV according to instructions Mounting on page 23. If you
install in the wrong direction, abnormal heat is generated, and may
lead to short-circuiting or burning the output element.
• G3RV is an SSR that generates heat. Please observe the ambient
temperature setting range of G3RV. If installing in an enclosed
space, set a fan, and ventilate.
• When mounting G3RV to DIN rail, firmly fits into the groove. If it is
not properly installed, there is a risk of it falling.
Wiring
• For the current to be applied, make sure a wire size with margin is used.
Otherwise, excessive heat generated by the wires may cause burning.
• Do not attempt to use the wire if the coat is torn. Not doing so may
result in electric shock.
• Always turn OFF the power supply before performing wiring. Not
doing so may cause electrical shock.
• The wires of the socket for G3RV socket should not be passed
through the same duct as that being connected to the high-voltage
power supply. Otherwise, inductive noise may damage the G3RV
or cause it to malfunction.
Push-In Plus Terminal Block
• Where strong electromagnetic field is generated
• Do not wire anything to the release holes.
• Where there is a risk of exposure to radioactivity
• Do not tilt or twist a flat-blade screwdriver while it is inserted into a release
• Do not use or store Sockets in environments that contain silicone
gas, sulfidizing gas (e.g., SO2 or H2S), or organic gas, or near
materials that contain silicone. Doing so may cause the contacts to
be unstable or to fail.
Handling
• Keep the G3RV well ventilated.
overheating.
Mounting
• Before you start wiring, please make sure that the socket is
securely attached to the mounting rail. If the socket is unstable, it
may come loose and risk of injury towards the workers.
• Please insert the flat-blade screwdriver to the bottom of the hole. If
you do not insert the flat-blade screwdriver correctly, the cable will
not be connected correctly.
• When lubricant such as oil is attached to the tip of the driver, the
driver will fall off, with a risk of injury towards the workers.
• Do not tilt the G2RV-SR/G3RV-SR after mounting to the support
The terminal block may be damaged if you insert the screwdriver
straight in.
• Do not allow the flat-blade screwdriver to fall out while it is inserted
into a release hole.
• Do not bend the wire past its natural bending radius or pull on it
with excessive force. Doing so may cause the wire disconnection.
• Do not insert more than one wire into each terminal (insertion) hole.
• To prevent wiring materials from smoking or ignition, confirm wire
ratings and use the wiring materials given in the following table.
Recommended Wire
Stripping length
(Ferrules not used)
0.5 to 1.5 mm2/AWG20 to AWG16
8 mm
Disposal
• When disposing of the product, do not put into the fire.
Common Accessories
There is a risk of short-circuiting or burning due to G3RV
hole on the terminal block. The terminal block may be damaged.
• Insert a flat-blade screwdriver into the release holes at an angle.
Common Precautions
condensation
• Please select the load within the rated range. Doing so may result
G3RV-SR
Operating and Storage Environments
Usage
rail. Doing so may apply excessive force to the mounting portion,
possibly damaging the product. Attach end plates (PFP-M) to
sandwich the product and hold it in place.
21
G2RV-SR/G3RV-SR
Precautions for Correct Use
G2RV-SR
• Do not use or store the product in the following locations. Doing so
• When replacing relays, there is a possibility the relay will pop out
may result in damage, malfunction, or deterioration of performance
and fall. Take care to prevent the relay from falling during
characteristics.
replacement.
• Where vibration or shock is directly transmitted to the body
• Where the socket could come into contact with a solvent or
alkaline agent
• Insert the short bar into the insertion hole in the correct orientation,
Push-In Plus Terminal Block
1. Connecting Wires to the Push-In Plus Terminal Block
Part Names of the Terminal Block
and insert until all terminals are all the way in.
• If using a short bar, install the short bar before performing wiring
Release hole
work.
Terminal (Insertion) hole
• A push-in Plus terminal block type and a screw terminal type have
different insertion positions, so a mixed installation using the same
short bar is not possible.
G3RV-SR
Connecting Wires with Ferrules and Solid Wires
Insert the solid wire or ferrule straight into the terminal block until the
end strikes the terminal block.
Orient correctly
and push all the
way in.
Release hole
Terminal
(Insertion) hole
Completely inserted
All terminals are inserted all the way in.
Ferrules or
solid wire
• If a wire is difficult to connect because it is too thin, use a flat-blade
screwdriver in the same way as when connecting stranded wire.
Common Precautions
Connecting Stranded Wires
Use the following procedure to connect the wires to the terminal block.
(1) Hold a flat-blade screwdriver at an angle and insert it into the
release hole.
The angle should be between 10°and15°. If the flat-blade
screwdriver is inserted correctly, you will feel the spring in the
release hole.
(2) With the flat-blade screwdriver still inserted into the release hole,
insert the wire into the terminal hole until it strikes the terminal
block.
(3) Remove the flat-blade screwdriver from the release hole.
Incorrect installation
Some terminals not inserted
completely.
Incomplete insertion
All terminals are not inserted
all the way in.
(1)
(3)
Flat-blade screwdriver
10 to 15°
(3)
(1)
(2)
Incomplete
insertion
Stranded Wires
(2)
Checking Connections
• After the insertion, pull gently on the wire to make sure that it will
not come off and the wire is securely fastened to the terminal block.
Common Accessories
• If you use a ferrule with a conductor length of 10 mm, part of the
conductor may be visible after the ferrule is inserted into the
terminal block, but the product insulation distance will still be
satisfied.
• Do not insert short bar in the hole for wire or screw driver, it may
cause the result of failure of pull out.
If insert short bar in the hole for wire or screw driver and try to pull
out, it may cause damage for short bar or socket and failure in
electric conductivity.
• Please insert P2RVC terminal into the short bar insertion hole of
G2RV-SR/G3RV-SR. If insert P2RVC into the release hole or
terminal (insertion) hole wrongly, P2RVC may stuck and can not
remove and it may cause result of damage on P2RVC and G2RVSR/G3RV-SR.
2. Removing Wires from the Push-In Plus Terminal Block
Use the following procedure to remove wires from the terminal block.
The same method is used to remove stranded wires, solid wires, and
ferrules.
(1) Hold a flat-blade screwdriver at an angle and insert it into the
release hole.
(2) With the flat-blade screwdriver still inserted into the release hole,
remove the wire from the terminal insertion hole.
(3) Remove the flat-blade screwdriver from the release hole.
(1)
(3)
Flat-blade screwdriver
Please turn off the power of input and output side and remove PLC
10 to 15°
(3)
(1)
interface unit when replacing mounting relays and SSRs for
maintenance.
22
(2)
Wire
(2)
G2RV-SR/G3RV-SR
Screw Terminal
3. Recommended ferrules and Crimp Tools
Recommended ferrules
• Screw terminal
Stripping
Ferrules
Recommended ferrules
length
Conduct
(mm)
length
Wago
(Ferrules Phoenix Contact Weidmuller
(mm2) (AWG)
(mm)
product
product
product
used)
0.25
24
0.34
22
0.5
20
0.75
18
1/1.25
18/17
10
AI 0,25-8
H0.25/12
12
AI 0,25-10
---
216-301
8
10
AI 0,34-8
H0.34/12
10
12
AI 0,34-10
---
8
10
AI 0,5-8
H0.5/14
216-201
10
12
AI 0,5-10
H0.5/16
216-241
216-202
--216-302
---
8
10
AI 0,75-8
H0.75/14
10
12
AI 0,75-10
H0.75/16
216-242
8
10
AI 1-8
H1.0/14
216-203
10
12
AI 1-10
H1.0/16
216-243
8
10
AI 1,5-8
H1.5/14
216-204
10
12
AI 1,5-10
H1.5/16
216-244
CRIMPFOX6
CRIMPFOX6T-F
CRIMPFOX10S
PZ6 roto
Variocrimp4
Recommended crimp tool
Note: 1. Make sure that the outer diameter of the wire is smaller than
the inner diameter of the insulating sleeve of the
recommended ferrule.
2. Make sure that the ferrule processing dimensions conform
to the following figure.
Stranded wires, without
ferrule
Stranded wires, with ferrule
and plastic collar
Stranded wires with ferrule,
without plastic collar
Single wire
Stripping
length
0.5 to 1.5 mm2
8 mm
0.5 to 1.5 mm2
8 mm
0.5 to 1.5 mm2
8 mm
2
8 mm
0.5 to 1.5 mm
• Tightening Torque
0.4 N • m
• Electric wiring
Use the electric wire of specified size as shown above. The length
of the that is not covered is 8 mm.
Screw terminal
G3RV-SR
1.25/1.5 17/16
8
10
Applicable wire
size
Wired type
G2RV-SR
Applicable
wire
8 mm
Stripping length
Operating latching lever (test switch)
When operating the latching lever for G2RV-SR701/501
series, use a 2.5 mm width flat-blade screwdriver.
8 to 10 mm
• Applicable flat-blade screwdriver
2.6 mm max.
3. If you use AWG24 to AWG22 (0.25 to 0.34 mm2) wires, UL
certification will not apply.
Flat-blade screwdriver with parallel cutting edge: shaft diameter
2.5 mm (3.0 mm max.)
Parallel cutting edge flat-blade screwdriver
Recommended Flat-blade Screwdriver
Use a flat-blade screwdriver to connect and remove wires.
Use the following flat-blade screwdriver.
The following table shows manufacturers and models as of 2015/Dec.
Side
Front
Shaft diameter 2.5 mm (3.0 mm max.)
Wide flat-blade screwdriver
Driver with a thick shaft cannot be used.
• Always turn OFF the power supply before operating latching lever.
2.5 mm dia.
• Return to its original state after using the latching lever.
• Do not use the latching lever as a switch.
0.4 mm
• Operation durability of the latching lever is 100 times or more.
2.5 mm
Common Precautions
1.9 mm max.
• Do not keep the latching lever ON for a long period of time (24
Model
Manufacturer
Wera
SZS 0,4×2,5
SZF 0-0,4×2,5 *
Phoenix Contact
0.4×2.5×75 302
Wiha
AEF.2,5×75
Facom
210-719
Wago
SDI 0.4×2.5×75
Weidmuller
* OMRON's exclusive purchase model XW4Z-00B is available to
order as SZF 0-0,4×2,5 (manufactured by Phoenix Contact).
hours or more) in order to maintain the operation check function.
Common Accessories
ESD 0,40×2,5
23
G2RV-SR/G3RV-SR
Method of operation of the latching lever (test
switch)
G2RV-SR
Incorrect Example
Countermeasure 1
Countermeasure 2
Recommended height of the duct is
1/2 or less of the height of the SSR
Duct or other object
blocking airflow
Duct or other object
blocking airflow
Open protective cover
Vertical
Direction
Duct or other object
blocking airflow
G3RV-SR
Keep the protective cover open when using the latching lever. Move
until the latching lever clicks to the ON position (ON state). After use
latching lever, in order to prevent malfunction, return the switch to
contact normal position (OFF state), and make sure the protective
cover is firmly closed.
Airflow
Metal
base
SSR
SSR
SSR
Do not enclose the SSR in a
duct of the same height.
It will interfere with the heat
dissipation of SSR.
Duct or
other object
blocking
airflow
Mounting surface
Close protective cover
Height of SSR
Mounting surface
Contact operating position (on-state)
Mounting surface
Contact normal position
Duct or other object
blocking airflow
Use ducts that have a
shallow depth, to provide a
sufficient ventilation area.
Duct or other object
blocking airflow
If the ducts cannot be made lower,
place the SSR on a metal base so
that it is not surrounded by the ducts.
Be aware of airflow
Duct or other object
blocking airflow
Exhaust
(Axial fan)
Using the latching lever
Example: check the operation of the relay and the sequence circuit
SSR
Input ratings
Smoothing capacitors are used in the internal circuits of AC/DCtype G2RV-SR devices. AC/DC-type G2RV-SR devices driven by
the sensor may not operate normally due to the characteristics of
the smoothing capacitor. When driving such devices by the
sensor, use the DC specification settings.
SSR
SSR
Inlet
Common Precautions
• If the air inlet or air outlet has a filter, clean the filter regularly to
prevent it from clogging to ensure an efficient flow of air.
• Since the G3RV uses electronic components, do not allow it to fall,
vibrate, or apply shock that exceeds the criteria. Doing so may
result in failure, malfunction, or deterioration of performance.
• Tighten screw terminal for G3RV at torque 0.4 N · m. It may cause
short-circuit failure or burning.
• Please use the voltage and current suitable for the input and
output terminal portion of G3RV. It may cause short-circuit failure
or burning.
• Do not place objects that may obstruct the proper ventilation for
outside or inside the inlet or exhaust port, and in the outside
vicinity.
• A heat exchanger, if used, should be located in front of the G3RV
to ensure the efficiency of the heat exchanger.
• Please observe the ambient temperature of G3RV. The rated
current of the G3RV is measured at an ambient temperature of
25°C.
• The G3RV uses a semiconductor in the output element.
Mounting
This causes the temperature inside the control panel to increase
due to heating resulting from the flow of electrical current through
Duct or other object blocking airflow
the load. The G3RV reliability can be increased by adding a
ventilation fan to the control panel to dispel this heat, thus lowering
Common Accessories
the ambient temperature of the G3RV.
SSR
10 mm min.
60 mm min.
(It suggests that life expectancy is doubled by each 10°C reduction
in ambient temperature.)
EMI
Vertical Direction
30 mm min.
80 mm min.
* When five or more are installed, install with 10 mm space between
each.
24
The G3RV is a Class A product (for industrial environments). When
used in a residential environment, it may cause radio interference.
In such case, the user may be required to take appropriate
measures.
G2RV-SR/G3RV-SR
For G2RV-SR/G3RV-SR
Common Accessories (order separately)
Short Bars
Appearance
No. of
poles
Pitch
Colors
2
Maximum energizing
current
PYDN-6.2-020@
3
6.2 mm
Minimum order
(Quantity)
Model *
Red (R),
Blue (S),
Yellow (Y)
4
10
20
G2RV-SR
Ordering Information
PYDN-6.2-030@
PYDN-6.2-040@
10
32 A
PYDN-6.2-100@
PYDN-6.2-200@
Note: Use for wiring to the adjacent socket.
* Replace the box (@) in the model number with the code for the covering color. @ color selection: R = red, S = blue, Y = yellow
Label
Appearance
Minimum order (Sheet)
(Pieces per sheet)
Model
G3RV-SR
XW5Z-P2.5LB1 *
5
(1 sheet/72 pieces)
XW5Z-P2.5LB2
* Available following June 2017 production.
Separate Plate
Appearance
Model
XW5Z-EP12
Appearance
I/O classification
Connection method
Push-In
For input
Common process
PNP
NPN
Screw
Push-In
Screw
G2RV-SR500-AP
Model
P2RVC-8-I-5-1
P2RVC-8-I-5
PNP
G2RV-SR700-AP
P2RVC-8-I-7-1
PNP
G2RV-SR500
G2RV-SR501
G3RV-SR500
P2RVC-8-O-5-1
NPN
For output
Applicable Models *
PNP
G2RV-SR700
G2RV-SR701
G3RV-SR700
P2RVC-8-O-5
P2RVC-8-O-7-1
Common Precautions
PLC interface unit
* Please make sure applicable models, P2RVC can not be used other combination than the above table.
Appearance
Type
Model
1m
PFP-100N
0.5 m
PFP-50N
1
DIN Tracks
End Plate *
Minimum order
(Quantity)
PFP-M
10
Spacer
PFP-S
Common Accessories
Parts for DIN Track Mounting
* When mounting DIN Track, please use End Plate (PFP-M).
Refer to your OMRON website for details on PFP-@.
25
G2RV-SR/G3RV-SR
Applicable Cables
G2RV-SR
Name
Appearance
Cables with Loose
Wires
P2RV-A@C
8 I/O
points
End B
1,000
P2RV-A100C
2,000
P2RV-A200C
3,000
P2RV-A300C
5,000
P2RV-A500C
1,000
P2RV-4-100C
2,000
P2RV-4-200C
3,000
P2RV-4-300C
5,000
P2RV-4-500C
1,000
P2RV-4-100IMC
2,000
P2RV-4-200IMC
3,000
P2RV-4-300IMC
5,000
P2RV-4-500IMC
1,000
P2RV-4-100IFC
2,000
P2RV-4-200IFC
3,000
P2RV-4-300IFC
5,000
P2RV-4-500IFC
L
70
OMRON PLC
Connecting
Cables with
Connectors (1:4)
P2RV-4-@C
32 output
points
G3RV-SR
L
OMRON PLC
Connecting
Cables with
Connectors (1:4)
P2RV-4-@IMC
300
32 input
points
L
Common Precautions
OMRON PLC
Connecting
Cables with
Connectors (1:4)
P2RV-4-@IFC
300
32 input
points
L
OMRON PLC
Connecting
Cables with Connectors
(1:1)
P2RV-A@C-OMR GRT1
8 output
points
OMRON PLC
Connecting
Cables with
Connectors (1:1)
P2RV-A@C-OMR NX
8 output
points
8 input
points
8 input
points
300
L
Removable
terminal block
Common Accessories
L
Connecting Cables
PLC interface
unit end
End A
Device
end
Cable
length L
(mm)
500
P2RV-A050C-OMR GRT1
1,000
P2RV-A100C-OMR GRT1
500
P2RV-A050IC-OMR GRT1
1,000
P2RV-A100IC-OMR GRT1
500
P2RV-A050C-OMR NX
1,000
P2RV-A100C-OMR NX
500
P2RV-A050IC-OMR NX
1,000
P2RV-A100IC-OMR NX
Applicable Connectors
Various devices
PLC I/O Units with MIL connectors (1:4)
CJ1W-OD232/OD262, etc.
PLC I/O Units with MIL connectors (1:4)
CJ1W-ID232/ID262, etc. *1
PLC I/O Units with Fujitsu connectors (1:4)
CJ1W-ID231/ID261, etc. *2
Slice I/O Units (1:1)
For inputs: GRT1-ID8-1
For outputs: GRT1-OD8-1
PLC I/O Units with screw-less clamp
terminal block (1:1)
For inputs: NX-ID4442
For outputs: NX-OD4256
*1. Use the P2RVC-8-I-@-1(PNP) as the PLC interface unit when connecting to the CJ1W-ID232/ID262 (or a unit with an equivalent terminal
arrangement).
*2. Use the P2RVC-8-I-@-1(PNP) as the PLC interface unit when connecting to the CJ1W-ID231/ID261 (or a unit with an equivalent terminal
arrangement).
26
G2RV-SR/G3RV-SR
Name
Appearance
32 input
points
End B
Device
end
PLC interface
unit end
32 output
points
Schneider Electric
PLC Connecting
Cables
P2RV-@C-SCH-@
L
300
16 output
points
L
300
32 output
points
Siemens PLC
Connecting Cables
P2RV-@C-SIM-@
L
300
16 input
points
300
32 input
points
32 output
points
L
300
1,000
P2RV-100C-SCH-A
2,000
P2RV-200C-SCH-A
3,000
P2RV-300C-SCH-A
5,000
P2RV-500C-SCH-A
500
P2RV-050C-SCH-B
1,000
P2RV-100C-SCH-B
2,000
P2RV-200C-SCH-B
3,000
P2RV-300C-SCH-B
5,000
P2RV-500C-SCH-B
500
P2RV-050C-SCH-C
1,000
P2RV-100C-SCH-C
2,000
P2RV-200C-SCH-C
3,000
P2RV-300C-SCH-C
5,000
P2RV-500C-SCH-C
500
P2RV-050C-SCH-D
1,000
P2RV-100C-SCH-D
2,000
P2RV-200C-SCH-D
3,000
P2RV-300C-SCH-D
5,000
P2RV-500C-SCH-D
500
P2RV-050C-SIM-A
1,000
P2RV-100C-SIM-A
2,000
P2RV-200C-SIM-A
3,000
P2RV-300C-SIM-A
5,000
P2RV-500C-SIM-A
500
P2RV-050C-SIM-B
1,000
P2RV-100C-SIM-B
2,000
P2RV-200C-SIM-B
3,000
P2RV-300C-SIM-B
5,000
P2RV-500C-SIM-B
500
P2RV-050C-SIM-C
1,000
P2RV-100C-SIM-C
2,000
P2RV-200C-SIM-C
3,000
P2RV-300C-SIM-C
5,000
P2RV-500C-SIM-C
500
P2RV-050C-SIM-D
1,000
P2RV-100C-SIM-D
2,000
P2RV-200C-SIM-D
3,000
P2RV-300C-SIM-D
5,000
P2RV-500C-SIM-D
500
P2RV-050C-SIM-E
1,000
P2RV-100C-SIM-E
2,000
P2RV-200C-SIM-E
3,000
P2RV-300C-SIM-E
5,000
P2RV-500C-SIM-E
Schneider Electric PLCs with 32-point
connectors (1:4)
For inputs: 140 DDI 353 00
For outputs: 140 DDO 353 00
Schneider Electric PLCs with
16-point connectors (1:2)
For inputs: BMX DDI 1602
For outputs: BMX DDO 1602
Siemens PLCs with
32-point connectors (1:4)
For inputs: 6ES7 321-1BL00-0AA0
For outputs: 6ES7 322-1BL00-0AA0
Siemens PLCs with
16-point connectors (1:2)
For inputs: 6ES7 321-1BH02-0AA0
Siemens PLCs with
32-point connectors (1:4)
For inputs: 6ES7 421-1BL-0AA0
For outputs: 6ES7 422-1BL-0AA0
Common Accessories
L
P2RV-050C-SCH-A
Common Precautions
32 input
points
500
Applicable Connectors
G3RV-SR
16 input
points
Connecting Cables
G2RV-SR
End A
Cable
length L
(mm)
27
G2RV-SR/G3RV-SR
PLC interface unit
Ratings / characteristices
G2RV-SR
Rated voltage
30 VAC/DC
Rated current
0.5 A/poles, 2 A/unit
Ambient operating temperature
−40 to 55°C
Vibration resistance
Shock resistance
Destruction
10 to 55 to 10 Hz, single amplitude 0.75 mm (double amplitude 1.5 mm)
Malfunction
10 to 55 to 10 Hz, single amplitude 0.75 mm (double amplitude 1.5 mm)
Destruction
300 m/s2
Malfunction
100 m/s2
Electrical schematic
Input
P2RVC-8-I-@-1 (PNP)
1....................8
14
P2RVC-8-I-5 (NPN)
1....................8
14
G3RV-SR
11
11
1 3 5 7 9
2 4 6 8 10
Common Precautions
Output
P2RVC-8-O-@-1 (PNP)
Common Accessories
28
1....................8
1 3 5 7 9
2 4 6 8 10
P2RVC-8-O-5 (NPN)
1....................8
A2
A2
A1
1 3 5 7 9
2 4 6 8 10
A1
1 3 5 7 9
2 4 6 8 10
G2RV-SR/G3RV-SR
Dimensions
(unit: mm)
PLC interface unit
G2RV-SR
Push-IN
P2RVC-8-I-5(-1)
P2RVC-8-O-5(-1)
49.60
67.16
7×6.20
29.30
Screw
P2RVC-8-I-7-1
P2RVC-8-O-7-1
67.16
12.68
7×6.20
29.30
Common Precautions
49.60
G3RV-SR
12.68
Common Accessories
29
G2RV-SR/G3RV-SR
(Except for PLC interface unit)
Common Accessories (order separately)
G2RV-SR
Dimensions
(unit: mm)
Short Bars
PYDN-6.2-@@ (6.2 mm)
2
L
Pitch
No. of poles
1.20
6.2 mm
9
14
6.20
L (Length)
2
12.4
3
18.6
4
24.8
10
62
20
124
Colors
Model *
Maximum carry
current
PYDN-6.2-020@
Red (R)
Blue (S)
Yellow (Y)
PYDN-6.2-030@
PYDN-6.2-040@
32 A
PYDN-6.2-100@
PYDN-6.2-200@
Note: Use the Short Bars for crossover wiring within one Socket or between Sockets.
* Replace the box (@) in the model number with the code for the covering color.
Separate Plate
XW5Z-EP12
G3RV-SR
12
56
63
Common Precautions
Parts for DIN Track Mounting
Refer to your OMRON website for details on the PFP-@.
Safety Precautions
Precautions for Correct Use
When mounting a short bar
Mounting a separate plate
• Intermediate pins can be bent by a tool or by hand and cut off for use.
• Use a flat-blade screwdriver to tighten the center top screw and
secure the plate. Loosen the screw to remove the plate from the
DIN rail.
M4 Screw
Common Accessories
Bend
Cut off
• The short bar can be cut to as many poles as needed. Insert the
tool from the plastic part side, and cut along the groove in the
plastic part between the terminals. When cutting, take care not to
break or deform the terminals.
However, because the metal on the cut surface will be exposed,
insulation countermeasures between adjacent products must be
ensured. Such countermeasures include widening the intervals
between products or using XW5Z-EP12 separate plates (order
separately).
Cut
30
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
OMRON Corporation
Industrial Automation Company
Authorized Distributor:
Kyoto, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2016-2017 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
CSM_6_9_0220
Cat. No. J214-E1-02
0617(0316)